Max10: ADC not working having .pof document

Disappointed, you need to guarantee doing this. Excite click the confirmation connect on the email address. You can also re also-post during your character.

  • Intel Society
  • Equipment Support Discussion boards
  • FPGA
  • Automated Devices
  • Max10: ADC not working having .pof file
  • Mark Question since the The
  • Mark Procedure given that Realize
  • Drift this topic having Latest Affiliate

I think you have that (or more) some slow or not as much as rated offers

is lil wayne dating ariana grande

I’m currently working with Max10M16DAF256 and i have a problem with the newest ADC. sof document it really works great. pof file the latest ADC doesn’t work any more, we.age ADC information is usually zero, given that other people areas work accurately.

When using

We have along with seen that when programming with .pof document whilst still being let the suppy voltage towards, the latest ADC work. But once reset the supply voltage (switch off and on again), it generally does not works any more.

Whether your latter then you will want to ensure see the manner in which you release the newest ADC Internet protocol address away from reset. Wait in reset ‘a nothing longer’ following power up. Disappointed this might sound a small vague. This appears to be an everyday situation on forum one to does not seem to have obtained a very clear, reliable services.

If this is the panel then you will want to test the above and make certain the new rail rise monotonically. There are no sequencing conditions if the usually do not increase correctly – maybe not meeting the fresh new Tramp big date – the computer often misbehave. Reference ‘Figure 3. Tracked Energy Offers Ramp Up’ from the ‘ fuel government user publication (

I additionally discover a similar issue with Max10 ADC an additional bond, but as if you told you there isn’t any service because of it.

The newest panel was our very own care about framework panel. The problem is that many of our boards work fine that have ” .pof “-document, and lots of of those understand this ADC state. Towards the boards with ADC condition, we investigated throughout the resources ones forums regrettably we missed any problem with the technology. For example listed above, the fresh new boards will work that have ” .sof ” and even ” .pof “-file if have voltage is often towards. After the also have current is reset, the new ADC does no more functions given that other people remains working accurately.

This will make me personally faith even more this issue tends to be strength associated. You might be clearly into the side of no matter what concern is offered you have got operating chat rooms.

Would you take a low operating board, unplug the advantage provides and electricity it of counter supplies? My personal issue is you to a not as much as ranked rail isn’t really as much as providing the inrush required and dips inducing the POR circuitry an excellent state, which (perhaps) isn’t recorded.

You may be correct. I did specific data regarding the strength supplies to possess Max10, therefore appears like our very own analog also provide takes some long up until they is located at full voltage peak (we’re using Max10 dual have unit, hence means two digital supplies and step 1 analog likewise have).

As in Max10 Strength government representative publication, it seems like just the past electric battery to have Max10 matter (affixed photo), therefore we tried to swtich with the analog likewise have basic and you can wait a little for they to arrive maximum level, and then mail order Macau brides start one other a couple digital provides, which simply take just few hundred or so s to-arrive max peak. This will help the not-operating ADC in order to become working sporatically (never working).

But when i need a functional board (ADC usually works) and you may do the reverse succession (i.elizabeth help several electronic offers into very first, then analogue also have), this new ADC remains performing (i requested that it cannot functions more).

Very somehow the new ADC problem identifies the advantage supply succession in addition to ramp time of strength offers, however, a very clear reason because of it problem could have been not receive but really.